Talk:Thermal Centrifuge (IndustrialCraft 2)

From Feed The Beast Wiki
Jump to: navigation, search

The Thermal Centrifuge takes 500 ticks per operation. GreenZombie76 (talk) 16:26, 6 November 2017 (UTC)

The code confirms that it uses 48 EU/t for 500 ticks per operation. The time it takes to heat up the thermal centrifuge depends on the recipe however. Built in recipes vary from 100 to 5000 heat, and it takes 1 tick per heat. 🐇Retep998🐇🐰Bunny Overlord🐰 16:45, 6 November 2017 (UTC)
Yes. The TC seems to have 3 energy use profiles: Heating (32 EU/t), Operation (48 EU/t) , Standby (?? EU/t) (if its empty but a redstone signal is applied to keep it heated. (also not sure what heat level is being maintained for Standby). GreenZombie76 (talk) 13:48, 7 November 2017 (UTC)